Mixellume
Series 65 Platform — Instrument Layer
Series 65 PRO
6.5-Digit Precision Measurement Instrument
Preliminary — Pre-Production
Document rev. DS-65PRO-001
Issue date June 2026
Status Pre-production validation
6.5 digit
Resolution class. DC voltage accuracy 35 ppm
3,200/s
Readings per second. High-speed capture mode
32k
Internal reading memory. Autonomous logging
SCPI-99
Automation-ready. USB + RS232 interfaces

Measurement passport architecture. The Series 65 PRO is designed as the first instrument layer in the Mixellume platform. Each reading carries noise state, drift model, calibration chain continuity, uncertainty envelope, and diagnostic context — making critical readings trusted decisions, not just numbers.

Measurement Passport — Context Layers
Noise state
filtered
Drift model
visible
Cal. chain
continuous
±
Uncertainty
attached
Diagnostics
ready
Technical Specifications
Parameter Specification
Display Resolution6.5 digits
DC Voltage (DCV)100 mV to 1000 V — Accuracy: 0.0035% (35 ppm)
AC Voltage (ACV)20 mV to 750 V — Accuracy: 0.15%
DC Current (DCI)10 µA to 3 A — Accuracy: 0.065%
AC Current (ACI)100 µA to 3 A — Accuracy: 0.15%
Resistance0.01 Ω to 100 MΩ (2-wire and 4-wire)
Frequency / Period3 Hz to 300 kHz — Accuracy: 0.01%
Capacitance100 nF to 1000 µF
TemperatureThermistor and thermocouple support
Measurement SpeedUp to 3,200 readings/sec
Memory Depth32,000 readings — internal autonomous logging
DC Noise Analysis EmbeddedStatistical analysis, peak detection, histogram
Special FunctionsDiode test, continuity, Zener test, 12 V functional generator
DisplayColor graphic LCD
InterfacesUSB, RS232 — SCPI-99 command set
FirmwareField-upgradeable. Measurement intelligence modules: filtering, drift, uncertainty, diagnostics
Key Measurement Functions
  • DC and AC voltage measurement — 100 mV to 1000 V
  • DC and AC current measurement — 10 µA to 3 A
  • Resistance 2-wire and 4-wire up to 100 MΩ
  • Capacitance, frequency, period measurement
  • Temperature via thermistor and thermocouple
  • Diode test, continuity, Zener diode test
  • Built-in 12 V functional generator
  • DC noise analysis: statistics, peak detection, histogram
Embedded Intelligence Modules
  • Adaptive noise filtering — signal dynamics preserved
  • Thermal drift model — visible and compensated
  • Calibration chain continuity tracking
  • Uncertainty envelope — attached to each reading
  • Diagnostic context — instrument health and anomaly detection
  • SCPI-99 remote control — full automation-ready command set
  • 32k internal memory for unattended data logging
  • Firmware-upgradeable measurement architecture
Interfaces and Connectivity
USB data logging RS232 SCPI-99 PC remote control Color graphic LCD Firmware OTA Automated test integration Long-term stability logging
Series 65 Platform — Roadmap Position
LayerProductStatus
Measurement instrumentSeries 65 PROPre-production — current instrument
Power and stimulusSeries 65 PowerRoadmap
Calibration continuitySeries 65 CALRoadmap
Reference lab platformSeries 65 LABRoadmap
Trusted DAQ data layerDAQ layerRoadmap

Preliminary specification. This document describes the Series 65 PRO pre-production instrument. All specifications, features, and performance parameters are subject to change without notice pending final validation and production release. Not for distribution as a commercial datasheet. For technical discussions and partnership enquiries: info@mixellume.com